Enviro 50-1095 Manuale Utente

Navigare online o scaricare Manuale Utente per Attrezzi Enviro 50-1095. Enviro 50-1095 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
PELLET STOVE
Bern
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE
OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY
OR EVEN DEATH
Contact your building or fire officials about restrictions and installation
inspection requirements in your area.
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED
PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
TECHNICAL MANUAL

50-1095
Vedere la pagina 0
1 2 3 4 5 6 ... 30 31

Sommario

Pagina 1 - TECHNICAL MANUAL

PELLET STOVEBernPLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS CO

Pagina 2 - Table of Contents

10InstallationHORIZONTAL EXHAUST THROUGH WALL INSTALLATION:Vent installation: install vent at clearances specified by the vent manufacturer.A chimney

Pagina 3 - Introduction

11Installation10. Install a vertical pipe, or if all requirements for direct venting are met, install vent termination. The stainless steel cap termin

Pagina 4

                    

Pagina 5

13HEARTH MOUNT INSTALLATION:InstallationRain capFlashing24"(61 cm)4"(10 cm)Tee withcleanout3" (7.5 cm)ClearanceSupportbracketType "

Pagina 6

14InstallationRain capStorm collarSeal plate (cover plate)Existing masonry flueVent pipe (single wallstainless flex pipe orsolid PL vent)Fireplace dam

Pagina 7

InstallationEXTERIOR MOUNTED EXHAUST BLOWER:The Bern can be equipped with an externally mounted exhaust blower. This optional kit includes all c

Pagina 8

InstallationTYPICAL THROUGH WALL WITH EXTERIOR BLOWER KIT INSTALLATION - HORIZONTAL TERMINATION:Electrical CableBern90° Elbow45°Elbow with Rodentscree

Pagina 9

17BernRoof SheathingRain CapRoof FlashingRoof RaftersCeiling JoistsVent PipeExterior WallSheathingOutside VentTerminationInstallationTYPICAL THROUGH W

Pagina 10 - Installation

InstallationTHERMOSTAT INSTALLATION:If the unit has been placed in the HI / LOW mode, the unit will be taken to a low or idle setting when the thermos

Pagina 11

19If the fire should happen to go out and the heat output indicator has been set on the lowest setting, the Slider Damper should be pushed in slightly

Pagina 12

2Introduction...3Ratin

Pagina 13

20InstallationOPTIONAL PANEL KIT:This kit must be installed before the unit is started. Figure 29: Screws at back of the cab side.Figure 27: Screws ab

Pagina 14

21Installation123Figure 30: Installing Hopper Lid.Installing Hopper Lid:1. Attach the hopper brackets to the back of the unit with a screw in e

Pagina 15

TroubleshootingDO NOT:● Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly.

Pagina 16

23TroubleshootingüPoor Quality Fuel – Insufficient energy in the fuel to produce enough heat to keep the stove burning or operational.üExhaust Tempera

Pagina 17

Troubleshooting7. The convection blower will not function normally.üClean all grill openings at the back and below unit .üPress the fan button; does t

Pagina 18

25Wiring DiagramConnectThermostatHereRedRedRedRedBrownBrownBrownBrownWhiteWhiteWhiteWhiteWhite115VWhite220VBlueWhiteWhiteOrangeOrangeOrangeOrangeYello

Pagina 19

Parts ListReference Number Description Part Number 1 120°F (49°C) Ceramic Fan Temperature Sensor EC-001 2 Auger Motor - 220V EF-001-220V3 High Limit T

Pagina 20

27Parts ListReference Number Description Part Number 17 Circuit Board, 2 second on time - 230V 50-116018 Auger with Paddles 50-116119 Brick Panel Set

Pagina 21

Parts Diagram - ComponentsBern - ComponentsFebruary 200528

Pagina 22 - Troubleshooting

29Parts Diagram - SteelBern - Steel ComponentsFebruary 2005

Pagina 23

3Introduction* This manual is designed for the technician in conjunction with the owner’s manual. *RATING LABEL LOCATION:The rating label is located o

Pagina 24

WarrantySherwood Industries Ltd. gives a five year limited warranty on all steel manufactured parts. A one-year warranty is provided on all electrica

Pagina 25 - Wiring Diagram

31NAME OF OWNER:_________________________________________ADDRESS:_____________________________________________________________________________________

Pagina 26 - Parts List

4IntroductionELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical c

Pagina 27

5InstallationDECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE:1. Check clearances to combustibles.2. Do not obtain combustion air from an attic, garag

Pagina 28 - Parts Diagram - Components

6InstallationAPPLIANCE DIMENSIONS AND SPECIFICATIONS:Figure 2: Dimensions of Bern. 151/2"(393 mm)187/8"(481 mm)171/2"(444 mm)195/8"

Pagina 29 - Parts Diagram - Steel

7InstallationCLEARANCES TO COMBUSTIBLES:Use a hearth pad that extends 6 inches (15 cm) in front of the unit when installing on a combustible floor.ALC

Pagina 30 - Warranty

fumes such as stairwells, covered breezeway, etc.2. Vent surfaces can become hot enough to cause burns if touched by children. Non-combustible shieldi

Pagina 31 - Installation Data Sheet

9InstallationEXHAUST LOCATION:83/4"(222mm)103/4"(273mm)Figure 6: Bern Inlet and Outlet Location. Base of unit to center of flue 10” (273

Commenti su questo manuale

Nessun commento